TOUCH SCREEN POWER Pro 300V 3000mA 300W – 110/230V
- 300V, 3000mA, 300W touch screen power supply.
- 5 pairs of outputs.
- 4.3-inch full-color touchscreen.
- Ideal for high-current applications such as blotting.
At 300V, 3000mA, 300W, the PowerPro 3AMP-M2 touch screen power supply is designed for virtually all high-current electrophoresis applications. The PowerPro 3AMP’s higher current output capability is perfect for electroblotting units with high-intensity plate electrodes, particularly Cleaver Scientific omniBLOT maxi, VS20 WAVE, and semi-dry blotting systems.
Electrotransfers may be performed as timed runs in constant or programmable mode via an intuitive touch screen interface to prevent overheating and buffer depletion. A run time extendable to a maximum of 999 minutes in constant mode is also useful for overnight transfers undertaken at constant low current in wire electrode systems.
The PowerPro 3AMP-M2 features a touch screen display and shares the built-in protocol and constant parameter features of the other PowerPro models. PowerPro 3AMP-M2 is the ideal power supply for:
- Vertical electrophoresis using omniPAGE Maxi
- Blotting using omniBLOT and semi-dry blotters

Note: The touch screen display shown is for illustration purposes only. Screen layout, displayed parameters, and available functions may vary depending on the specific power supply model, voltage range, and product configuration.
| Unit Dimensions (cm) | 21.5 x 33.5 x 10.4 |
|---|---|
| Weight (Kg) | 2.1 |
| Construction | PC housing, ABS faceplate |
| Timer | 1. Constant: 9999 (min) with alarm / continuous 2. Program: 999 (min) with alarm / continuous |
| Resolution | 1V, 10mA |
| Input Voltage | 100-240V: 47-60Hz, 410W |
| Operating Temperature | 4℃~ 40℃ |
| Operating environment | ≤95% RH |
| Display | 4.3” Colorful Touch Screen |
| Controller | Microprocessor |
| Safety Features | Shrouded plugs and sockets |
| Compliance Marks | CE |
| Maximum Voltage (V) | 300 |
| Maximum Current (mA) | 3000 |
| Maximum Power (W) | 300 |
| Number of Output Pairs | 5 |
| Operating Modes | Constant Parameter, Programmable 6 Step Programme. Pre-programmed settings |
| Program Storage | 100 programmed files |
| Program Multi-Step | Up to 30 steps |
| Type of Output | 1. Voltage or Current with automatic crossover 2. When target constant mode is set, system automatically adjusts the two other parameter to maximum to allow constant run |
| Output Diameter (mm) | 4 |
| USB port | For exported last run report |
| For exported last run report | Yes, last running data |
| No Load Detection | Yes |
| Overload Detection | Yes |
| Ground Leakage Detection | Yes |
| Over Temperature Protection | Yes |






